X Close
X

UPS & Inverters - A.K. Battery


  • Microtek UPS SEBz 900 VA

    MICROTEK UPS EB models are designed using latest state-of-the-art Technology for Better Performance & High Reliability. * MICRO-CONTROLLER BASED Intelligent Control Design. *Display Indications (Status & Fault) * CCCV Technology with Auto Trickle Mode * Smart Overload Sense and Short Circuit Protection * Battery State Monitoring * Easily Serviceable * Multi Stage Battery Charger * Mains Input Voltage Range Selection Technical Specifications Input Voltage (Standard Range) (Narrow Range) : 100V~300V / 180V~260V Output Voltage on Mains Mode : Same as Input Output Voltage on UPS Mode : 210V ± 10% Output frequency on UPS Mode : 50 Hz ± 0.1 Hz Switching from Mains to UPS and from UPS to Mains : Automatic Output Waveform on Mains Mode : Same as Input Output Waveform on UPS Mode : PURE SINE WAVE Battery Charging Current :Constant Charging Approx 10% of The Rated Battery Current in AH Charger : Power Factor Controlled Boost Technology Efficiency : > 80% UPS Overload / UPS Short Circuit : 110% / 300% UPS Transfer Time : ≤ 15 msec. Technology : Digital Signal Controller (DSC) Based Intelligent Control Design Auto Reset Feature : Yes

  • Microtek UPS SEBz 1100 VA

    MICROTEK UPS EB models are designed using latest state-of-the-art Technology for Better Performance & High Reliability. * MICRO-CONTROLLER BASED Intelligent Control Design. *Display Indications (Status & Fault) * CCCV Technology with Auto Trickle Mode * Smart Overload Sense and Short Circuit Protection * Battery State Monitoring * Easily Serviceable * Multi Stage Battery Charger * Mains Input Voltage Range Selection Technical Specifications Input Voltage (Standard Range) (Narrow Range) : 100V~300V / 180V~260V Output Voltage on Mains Mode : Same as Input Output Voltage on UPS Mode : 210V ± 10% Output frequency on UPS Mode : 50 Hz ± 0.1 Hz Switching from Mains to UPS and from UPS to Mains : Automatic Output Waveform on Mains Mode : Same as Input Output Waveform on UPS Mode : PURE SINE WAVE Battery Charging Current :Constant Charging Approx 10% of The Rated Battery Current in AH Charger : Power Factor Controlled Boost Technology Efficiency : > 80% UPS Overload / UPS Short Circuit : 110% / 300% UPS Transfer Time : ≤ 15 msec. Technology : Digital Signal Controller (DSC) Based Intelligent Control Design Auto Reset Feature : Yes

  • Microtek UPS SEBz 1600 VA

    MICROTEK UPS EB models are designed using latest state-of-the-art Technology for Better Performance & High Reliability. * MICRO-CONTROLLER BASED Intelligent Control Design. *Display Indications (Status & Fault) * CCCV Technology with Auto Trickle Mode * Smart Overload Sense and Short Circuit Protection * Battery State Monitoring * Easily Serviceable * Multi Stage Battery Charger * Mains Input Voltage Range Selection Technical Specifications Input Voltage (Standard Range) (Narrow Range) : 100V~300V / 180V~260V Output Voltage on Mains Mode : Same as Input Output Voltage on UPS Mode : 210V ± 10% Output frequency on UPS Mode : 50 Hz ± 0.1 Hz Switching from Mains to UPS and from UPS to Mains : Automatic Output Waveform on Mains Mode : Same as Input Output Waveform on UPS Mode : PURE SINE WAVE Battery Charging Current :Constant Charging Approx 10% of The Rated Battery Current in AH Charger : Power Factor Controlled Boost Technology Efficiency : > 80% UPS Overload / UPS Short Circuit : 110% / 300% UPS Transfer Time : ≤ 15 msec. Technology : Digital Signal Controller (DSC) Based Intelligent Control Design Auto Reset Feature : Yes

  • Microtek UPS SOLAR SS 1660VA

    The sun is the most well distributed natural source of energy and solar power harnesses this abundant resource. As energy conservation is the need of the hour, Solar energy based applications are fast catching-up.Microtek’s SOLAR UPS provides access to this free source of solar energy. The New Generation Range of UPS Sinewave Solar are based on DSC (Digital Signal Controller) technology. Specially designed Sinewave SOLAR UPS Model for backup for computers. Microtek Solar UPS is Integrated with an in-built 30Amp Solar Charge Controller, which enables the conversion of solar power to electricity. Dual Charging Mode - MAINS Mode & SOLAR Mode. Best for Long Power Cuts / Rural areas. While charging battery from Solar Power as against Mains, 98% of efficiency is delivered. Microtek Solar UPS always gives first preference to Solar Power while charging the battery. It senses the availability of Solar Power/Mains Power and gives charging preference to the Solar Power Charge and switches to the Mains Power only when the Solar Power is not available. The UPS has been specially designed, so that you get maximum benefit from the sun and charging from Solar Panel will cut down your electricity consumption while charging from mains. You will get Longer BACKUPS during powercuts, as the UPS will use power from the solar panel also. Highly Efficient Transformer, helps in Fast charging of the battery & Saves Energy. It increases the life of Battery as a Solar PV panel converts sunlight directly into pure direct current(DC). Bypass Switch- This additional bypass switch enables you to isolate your UPS from mains, whenever needed Upto 500W Solar Panel for SS1130 Model. Upto 1000W Solar Panel for SS1660 Model.